CODE: FAULT LED • Check for Gas Odor First

Suburban & Dometic/Atwood DSI Water Heater Fault Light

System: Heating & Hot Water • Tools needed: Flashlight (for external visual check only)

Suburban & Dometic/Atwood DSI Water Heater Fault Light
Code: FAULT LEDBrand: Suburban / DometicSystem: Heating & Hot Water

First: If you smell propane, hear hissing, have an active propane or CO alarm, or anyone has CO symptoms (dizziness, headache, nausea), evacuate everyone right away without touching switches or stove igniters. Call 911 from outdoors. When no gas odor or alarm exists, a red FAULT (or auto-spark check) light beside your interior water heater switch means the Direct Spark Ignition board locked out after failing to establish a propane flame. Confirm the water heater tank is 100% full of water, verify your propane cylinder valve is open and 12V battery power is healthy, and try one normal interior switch OFF/ON reset. Route any tripped overheat safety fuse, flame rollout, or recurring lockout to a qualified RV tech.

01 • Fault Specs & Root Cause

Fault Summary

What to Know Details
Screen Code / Blink PatternFAULT LED
Appliance MakerSuburban / Dometic / Atwood
Camper SystemHeating & Hot Water
How Urgent Is It?Check for Gas Odor First
Basic Tools NeededFlashlight (for external visual check only)
01

What Is Happening Inside the Unit

Tank-style RV water heaters use a 12-volt Direct Spark Ignition (auto-spark) control module to open the gas electric gas valve and spark across the burner tube while monitoring for flame current. If no flame is sensed within the spark try, the module shuts the gas valve and turns on the interior FAULT indicator.

Read deeper field notes

Lockouts commonly occur when the propane tank is empty or closed, air remains in the line after a cylinder swap, 12V house battery voltage is low, or debris blocks the exterior burner/flue path. Inaddition, water heaters incorporate high-heat safety limits (such as high-heat safety switches or single-use overheat safety fuses) if a high-limit or overheat safety fuse trips, it signals an overheating or flame-rollout fault that must be inspected by a trained RV tech rather than bypassed or blindly reset.

02 • Troubleshooting Steps

Step-by-Step Fix

Step 1 of 5

Emergency Gas & Carbon Monoxide Check First

Before touching any switches or opening exterior compartments. If you smell propane, hear gas hissing, have an active propane or carbon monoxide (CO) alarm, or anyone feels dizzy, headachy, or nauseous, evacuate everyone and pets right away without operating switches, appliances, or stove igniters. Call 911 or the fire department from a safe outdoor location and do not re-enter or restart until cleared. Remember that absence of smell alone does not prove safety. CO is odorless and propane odor can fade.

Step 2 of 5

Confirm the Water Heater Tank Is Full of Water Before turning on Any Switch

With both the propane gas and 120V Electric water heater switches turned OFF, open an indoor hot water faucet and verify a steady, solid stream of water flows without sputtering air. Never turn on either the gas burner or the 120V electric heating element if the tank is empty, drained, or sitting in winterizing bypass mode.

Step 3 of 5

Verify Propane Cylinder Supply & 12V Battery Power (No Stove Purging)

When no odor or alarm is present, verify your exterior propane tank valve is slowly turned fully open and your 12V house battery is charged. Do not light kitchen stove burners to purge air or judge gas pressure during fixing.

Step 4 of 5

Visually Check the Exterior Compartment With All Systems Off and Cool

With both gas and 120V electric water heater switches turned OFF and the exterior parts cool, open the outside access door and look with a flashlight for obvious outer vent blockages, soot marks, or scorched wiring. Do not take apart the burner tube, do not bend spark electrodes. Never attempt to press or reset high-heat limit buttons or overheat safety fuses. Meanwhile, the unit is hot, powered on, or under pressure.

Step 5 of 5

Perform One Interior propane Switch Reset & Route Persistent Faults to Service

If there is no soot, no scorched wiring, and no gas smell, turn the interior water heater propane switch OFF, wait 15 to 30 seconds per your owner’s manual, and turn it back ON once. If the FAULT light returns—or if a high-heat safety switch or overheat safety fuse has tripped. Turn both water heater switches OFF and contact a qualified RV tech.

⚠️ What NOT To Do (Saves You Big Money)

Never pull or flip the exterior brass pop-off pressure valve lever. Meanwhile, the water heater is hot, heating, or under pressure (severe scalding hazard!). Never tamper with or plug a pop-off pressure valve. Never bypass a overheat safety fuse or high-heat safety switch. Never dry-fire gas or electric heat on an empty tank. Never perform live multimeter testing or DIY burner/electrode taking apart.

Stop & Call a Repair Tech When: Call 911 Immediately from outdoors for any propane odor or CO alarm. Call a qualified RV service tech whenever a high-heat safety switch or overheat safety fuse trips, if you see black soot or flame rollout marks around the burner mouth, if the pop-off pressure valve drips continuously or needs service, or if the FAULT light returns after one interior switch reset.

Spare Parts to Carry

  • Printed copy of your exact Suburban or Dometic/Atwood water heater owner’s manual
  • Flashlight for hands-free visual checks of the exterior water heater bay
  • Inline RV water pressure regulator matched to your RV maker’s recommended PSI limit

Common Questions

Why does water sometimes weep from the exterior brass pop-off pressure valve, and is it safe to pull the lever while hot?

NEVER pull or flip the exterior pop-off pressure valve lever while the water heater is hot, heating, or under pressure—superheated water can spray out and cause severe scald burns! Water expansion during heating can cause minor weeping if the tank’s internal air pocket has dissipated. Per Dometic and Suburban manuals, turn off all gas and electric water heaters, shut off the water supply, and let the water cool completely before following the exact owner’s manual procedure to re-establish the air pocket or having a RV tech inspect the valve.

What does it mean if the clear-sleeved overheat safety fuse or high-heat safety switch tripped?

A tripped overheat safety fuse or high-heat safety switch means unsafe heat or flame rollout occurred outside the normal burner path—often from an obstructed burner tube or flue. Never bypass or bridge a overheat safety fuse. Never reset limits on a hot or powered on heater. Shut the heater off and have a qualified RV tech clear the root burner fault and replace factory safety parts.

Can I turn on the water heater right after hooking up my city water hose?

Only after you open an indoor hot water faucet and allow the water heater tank to fill completely until water flows steadily without air sputters. Turning on either the 120V electric element or propane gas burner on an empty or partially empty tank can destroy the element and overheat the tank in seconds.

More in The Camper Almanac

Related Guides