CODE: E1 / E2 • Check for Gas Odor First (E2 Requires Service)

Furrion Tankless Water Heater E1 & E2 Error Codes

System: Heating & Hot Water • Tools needed: Flashlight (for external visual check only)

Furrion Tankless Water Heater E1 & E2 Error Codes
Code: E1 / E2Brand: FurrionSystem: Heating & Hot Water

First: If you smell propane, hear hissing, have an active propane or CO alarm, or anyone has CO symptoms (dizziness, headache, nausea), evacuate everyone right away without touching switches or stove igniters. Call 911 from outdoors. Outside of an emergency, check which code is on your Furrion wall controller! Per Lippert’s official Furrion FWH09AFA fixing guide, E1 means Ignition Failure (flame did not ignite). By contrast, E2 is a False Flame / System Fault (not a shower water-mixing or flow-screen issue). For E2, shut the water heater off right away and contact Furrion or a qualified RV service tech. For E1 with no gas odor, verify your propane tank is open and 12V power is healthy, then try one operator reset.

01 • Fault Specs & Root Cause

Fault Summary

What to Know Details
Screen Code / Blink PatternE1 / E2
Appliance MakerFurrion
Camper SystemHeating & Hot Water
How Urgent Is It?Check for Gas Odor First (E2 Requires Service)
Basic Tools NeededFlashlight (for external visual check only)
01

What Is Happening Inside the Unit

On Furrion FWH09AFA-series tankless RV water heaters, Lippert’s official fixing table defines Error E1 as an ignition failure—the burner attempted to light when hot water was requested. However, no flame was established within the trial period (often due to a closed or empty propane cylinder, low 12V battery supply, or a gas-supply fault).

Read deeper field notes

By contrast, Lippert’s official fixing guide defines Error E2 on the Furrion tankless water heater as a false flame / system fault. The control board senses a flame signal when the gas valve is supposed to be closed, or detects an internal control/valve fault.

Because a false-flame fault involves the burner safety circuit, it is not solved by adjusting shower cold-water knobs or cleaning water screens and requires qualified service.

02 • Troubleshooting Steps

Step-by-Step Fix

Step 1 of 5

Emergency Gas & Carbon Monoxide Check First

If you smell propane, hear hissing gas, have a sounding propane or carbon monoxide (CO) detector, or anyone feels dizzy, headachy, or nauseous, evacuate everyone and pets outside right away without touching light switches, water-heater controls, or stove igniters. Call 911 or the fire department from a safe outdoor location and do not re-enter or restart until cleared. Remember that absence of smell alone does not prove safety—CO is odorless and propane odor can fade.

Step 2 of 5

If Your Display Shows E2 (False Flame / System Fault). Shut Down & Call Service

Per Lippert’s official Furrion water heater fixing guide, E2 indicates a false flame or internal system fault. Do NOT try to clear E2 by adjusting cold-water mixing at the shower faucet, dismantling water flow turbines, or repeatedly flipping power switches. Turn the water heater off, close the exterior propane cylinder valve if plainly safe from outdoors, and contact Furrion customer support or a qualified RV tech to inspect the gas valve, flame sensor, and control board.

Step 3 of 5

For E1 Only (With No Gas Odor). Verify Propane Cylinder Supply & 12V Power

If your controller shows E1 (ignition failure) and there is no gas odor or alarm, check your exterior propane cylinders to confirm a tank with fuel is slowly turned fully open, and check that your RV’s 12-volt house battery is charged above normal operating voltage. Do not light kitchen stove burners to purge gas lines or judge gas pressure.

Step 4 of 5

For E1 Only. Check Exterior Vent Clearance & Water Supply Valves

With the water heater switched OFF and cool, visually inspect the exterior water heater door from outside to make sure the exhaust outlet and air intake louvers are not blocked by mud-dauber nests or debris, and confirm your RV’s exterior water-heater bypass valves are set to normal operation per your RV manual.

Step 5 of 5

For E1 Only. Perform One normal Operator Reset

Turn off the hot water tap, follow your exact Furrion water heater owner’s manual to reset the controller once, and open a hot faucet to test a single ignition cycle. If E1 returns after one reset, turn the unit OFF and contact an authorized RV tech. Do not repeatedly cycle power or open the sealed burner assembly.

⚠️ What NOT To Do (Saves You Big Money)

Never treat Furrion tankless Code E2 as a water-flow or shower-heat issue. Never repeatedly reset an E2 false-flame fault or an E1 ignition lockout. Never light stove burners to purge propane during a fault check. Never open the internal burner box, gas valve, or pressure relief valve while hot or under pressure.

Stop & Call a Repair Tech When: Call 911 from a safe outdoor location if you smell propane or an alarm sounds. Contact Furrion support or a qualified RV service tech right away for any E2 false-flame/system fault, for any E1 ignition fault that persists after verifying propane supply and performing one operator reset, or for any water leak or exhaust fan fault.

Spare Parts to Carry

  • Printed copy of your exact Furrion tankless water heater model manual (e.g., FWH09AFA)
  • Flashlight for safe exterior visual checkup of the exhaust louver
  • Working, non-expired RV propane and carbon monoxide detectors

Common Questions

What is the real difference between E1 and E2 on a Furrion FWH09AFA tankless water heater?

Per Lippert’s official Furrion fixing table, E1 is an ignition failure. The burner failed to light or sense flame during startup. Meanwhile, E2 is a false-flame / system fault. Flame signal detected when the burner should not be lit, or an internal control/valve fault. E2 is a safety fault that requires shutting the unit down and contacting Furrion or a qualified RV tech.

Why shouldn’t I keep resetting my Furrion water heater if E1 happens three times in a row?

Repeatedly resetting an ignition lockout without correcting the underlying fuel or ignition issue can push unburned gas into the burner chamber or cause a delayed-ignition pop. If one normal operator reset after confirming an open propane valve does not restore normal operation, turn the heater off and call a trained RV tech.

What does a blank display mean on my Furrion water heater wall controller?

A dark wall controller usually indicates that the exterior manual power rocker switch behind the outside access door is turned off, the 12V DC branch fuse has opened, or the RV’s main 12V battery disconnect switch is off. Always check your exact model manual before servicing.

More in The Camper Almanac