CODE: E0 – E6 CODES • 15-Min Flashlight Fix

Girard GSWH-2 Tankless Water Heater Error Codes

System: Heating & Hot Water • Tools needed: Flashlight, pliers wrapped in a cloth, and a soft dry brush

Girard GSWH-2 Tankless Water Heater Error Codes
Code: E0 – E6 CODESBrand: GirardSystem: Heating & Hot Water

First: If you smell propane, hear hissing, have an active propane or CO alarm, or anyone feels dizzy or nauseous, evacuate everyone immediately without touching switches or stove igniters, and call 911 from outdoors. Only after ruling out a gas leak: on a Girard GSWH-2 tankless RV water heater, the wall controller displays E1 (ignition failure / low gas supply), E2 (flame loss during operation), E3 and E6 (overheating / scald-protection shutoffs. Stop running hot water immediately), E4 (water temperature sensor fault), and E5 (blower motor / air-proving fault). Do not light a stove to purge lines. Follow the code-specific steps below.

01 • Fault Specs & Root Cause

Fault Summary

What to Know Details
Screen Code / Blink PatternE0 – E6 CODES
Appliance MakerGirard
Camper SystemHeating & Hot Water
How Urgent Is It?15-Min Flashlight Fix
Basic Tools NeededFlashlight, pliers wrapped in a cloth, and a soft dry brush
01

What Is Happening Inside the Unit

According to the Girard GSWH-2 manual, E1 means the burner failed to ignite initially. Meanwhile, E2 means the flame went out during heating (often due to low propane pressure, wind gusting into the flue, or an empty cylinder).

Read deeper field notes

E5 means the control board did not detect the proper burner blower motor speed signal before ignition. Codes E3.

Water over-heat above ~140°F. And E6.

Critical scald-protection cutoff above ~149°F. Trigger when water flow drops too low or a winter bypass valve is partially open.

Never keep running scalding water when E3 or E6 appears. Shut the tap right away, verify your water heater bypass valves are in normal summer position, and call a RV tech if overheating codes recur.

02 • Troubleshooting Steps

Step-by-Step Fix

Step 1 of 5

Step 1 (Life Safety First). Check for Gas Odor or CO Alarm Before Touching Anything

If you smell propane gas inside or outside the camper, if your propane/CO alarm is sounding, or if anyone feels dizzy, nauseous, or headachy, STOP fixing right away. Extinguish all flames and smoking materials, do not operate electrical switches or appliances, get everyone outside into fresh air, shut the propane tank valve only if safe to reach outside, and call 911 or your propane supplier from a safe distance. Keep your propane and carbon monoxide detector powered at all times.

Step 2 of 5

For E3 or E6 (Overheat). Run ONLY Hot Water & Clean Inlet Screen

Set the Girard digital screen to 108°F and open ONLY the hot shower knob. Never mix cold water or hit a showerhead trickle switch! Still getting E6. Turn water off, open the outside Girard door, unscrew the brass cold-water inlet swivel, and brush sand or pink antifreeze slime off the tiny wire screen.

Step 3 of 5

For E5 (Blower Fan Fault). Check 12V Battery & Outside Vent

E5 means the 12-volt exhaust blower motor didn’t spin fast enough. First plug into campground power or charge a weak camper battery above 12.2 volts! Then shine a flashlight into the exterior Girard exhaust vent to gently remove any mud-dauber wasp nests or wedged leaves.

Step 4 of 5

For E0 or E4 (Water Sensor Wires). Re-Seat the Tiny Plug Clips

E0 (outlet water thermometer) and E4 (inlet water thermometer) almost always mean a loose two-wire sensor plug after a bumpy highway drive! Switch the Girard 12V fuse off, open the outside access panel, find the two small wire probes clipped onto the copper water pipes, and push their white plugs tight.

Step 5 of 5

Smooth Out Pulsing RV Water Pumps That Confuse the Flow Wheel

Getting random E1/E2/E6 shutoffs ONLY when running off your fresh-water tank pump. While city water hookups work great. Pulsing "burp-burp-burp" water pumps drop flow every second—partially clogged pump strainer cups or tiny air leaks on the pump intake hose are easy five-minute fixes!

⚠️ What NOT To Do (Saves You Big Money)

Never toss out the tiny cone-shaped wire screen inside the Girard’s cold-water brass inlet fitting just. That is because it had sand on it! Without that 30-second washable screen, one pebble of campground gravel swims straight inside and jams the spinning magnetic water-flow wheel permanently.

Stop & Call a Repair Tech When: Call an RV tech if you smell raw propane, if E3 stays locked open even when the pipes are stone-cold (meaning the small clip-on overheat switch burned out, or if E5 persists with clean vents and 13+ battery volts).

Spare Parts to Carry

  • Inline garden-hose sediment filter to keep sand out of your Girard screen
  • Spare rubber washer for the 1/2-inch water-heater brass inlet swivel
  • High-flow RV showerhead with zero trickle-choke restriction

Common Questions

Do I have to press a reset button on the Girard GSWH-2 to clear an error code?

Usually no! On most GSWH-2 faults (like E1, E2, or E6), simply turning the hot water faucet completely OFF for ten seconds and opening the hot tap wide again on its own clears the code and tries a fresh start.

Why does the red flame icon come on only when water flows past 0.8 GPM?

Safety! If the Girard lit its massive 42,000-BTU burner on a tiny trickle of water, it would turn water into scalding steam in two seconds. Always open the hot faucet briskly all the way!

Can winter freeze damage cause E0, E4, or leaks in spring?

Sadly yes. If water was left sitting inside the copper pipes over a 20-degree winter freeze, ice splits the thin copper tubing or cracks the sensor fittings! Always peek inside the outside Girard door when turning water on each spring.

More in The Camper Almanac

Related Guides