CODE: PE2 / E2 / E7 • Shut Off / Do Not Bypass at Campground

EMS Surge Protector PE2, E2 & E7 Faults

System: 12V & Shore Power • Tools needed: Flashlight and your exact surge protector, RV, and generator owner manuals

EMS Surge Protector PE2, E2 & E7 Faults
Code: PE2 / E2 / E7Brand: ProgressiveSystem: 12V & Shore Power

First, check which brand of surge protector you own so you do not mix up the codes! On a Progressive Industries surge protector, E2 means an active Open Ground and PE2 means the Previous Error was Open Ground. On a Hughes Power Watchdog, Open Ground is E7 (whereas Hughes 50-amp E2 means a Line 2 voltage fault) ifyou see an Open Ground fault (progressive E2/PE2 or Hughes E7) on a campground power post, turn the power post breaker OFF, unplug, do NOT bypass the surge protector or try other outlets on a damaged power post, and report it to park management for an electrician to repair. If you are using a portable floating-neutral generator, check your exact generator, RV, and surge protector manuals before using a neutral-ground bonding plug.

01 • Fault Specs & Root Cause

Fault Summary

What to Know Details
Screen Code / Blink PatternPE2 / E2 / E7
Appliance MakerProgressive Industries / Hughes Watchdog
Camper System12V & Shore Power
How Urgent Is It?Shut Off / Do Not Bypass at Campground
Basic Tools NeededFlashlight and your exact surge protector, RV, and generator owner manuals
01

What Is Happening Inside the Unit

A smart wiring Management System (surge protector) checks the incoming AC power source before allowing power into your RV. At a campground power post, the safety ground wire must provide a continuous fault-return path so that a short circuit trips the breaker rather than turning on the metal skin and frame of your RV ("hot skin").

Read deeper field notes

When a campground power post has a broken or disconnected ground wire, Progressive Industries units display E2, or pE2 for previous open ground. And Hughes Power Watchdog units display E7.

Important code distinction. Do not confuse Progressive Industries E2 (Open Ground) with Hughes Power Watchdog 50-amp E2!

Per Hughes Power Watchdog instructions, E2 on a 50-amp Watchdog indicates a Line 2 voltage fault. High or low voltage on Line 2.

Meanwhile, E7 indicates a missing ground. Separately, some portable inverter generators use an isolated ("floating") neutral design that causes an surge protector to report an open ground unless configured per the maker’s instructions.

02 • Troubleshooting Steps

Step-by-Step Fix

Step 1 of 5

Verify Your surge protector Brand and Exact Code Meaning First

Confirm which device is displaying the code. On Progressive Industries surge protector units (such as PT30C/PT50C), E2 is an active Open Ground and PE2 indicates the previous fault was Open Ground. On Hughes Power Watchdog units, Open Ground is E7. Meanwhile, E2 on a 50-amp Watchdog is a Line 2 voltage fault (under 104V or over 132V).

Step 2 of 5

At a Campground power post. Turn the Breaker OFF and Unplug

If an open ground. Progressive E2/PE2 or Hughes E7, or voltage fault appears at a campground power post, switch the power post circuit breaker completely OFF first and unplug your RV cord. If you used a plug adapter or extension cord, test the surge protector plugged directly into the matching power post outlet without the adapter to rule out a broken ground pin inside the adapter.

Step 3 of 5

Report Faulty Campground power posts to Park Staff. Do Not Use Other Slots on a Faulty Post.

If the surge protector reports an open ground or wiring fault when plugged directly into the campground power post, turn the power post breaker OFF and unplug. Do not try plugging into a neighboring 20A, 30A, or 50A outlet on the same faulty power post—a damaged or ungrounded power post can share a damaged ground or neutral bus across all outlets in the box. Notify campground management so a licensed electrician can repair the power post or assign you a verified safe campsite.

Step 4 of 5

On a Portable Generator. Check Your Exact Generator, RV & surge protector Manuals

If Progressive E2 or Hughes E7 appears ONLY when connected to a portable inverter generator, check your generator’s owner manual to verify whether it uses a floating neutral, and check your surge protector and RV/inverter manuals before inserting a neutral-ground bonding plug into a generator outlet. Never assume every generator or RV inverter setup uses a bonding plug identically, and remove any generator bonding plug before using the generator for standalone cord-and-plug tools.

Step 5 of 5

Operate on 12V House Battery Power While Waiting for a Safe power post

If a campground power post has an open ground and no new site is right away available, leave the faulty power post breaker OFF and your shore cord completely unplugged. Use your RV’s 12V DC battery lighting and systems. Following all appliance manuals and ensuring propane/CO detectors are active. Until a qualified electrician clears the campground power post.

⚠️ What NOT To Do (Saves You Big Money)

NEVER bypass your surge protector. Never plug your RV directly into a campground power post that reported an open ground (progressive E2/PE2 or Hughes E7). Never try another outlet on a power post with a known grounding/wiring fault. NEVER use a generator neutral-ground bonding plug on a campground power post, home outlet, or bonded onboard generator!

Stop & Call a Repair Tech When: Request a licensed campground electrician whenever a park power post triggers an surge protector open-ground or voltage fault. Call a qualified RV tech if an onboard RV generator triggers an open-ground code or if your RV’s own shore cord or adapter has damaged prongs.

Spare Parts to Carry

  • Printed fault-code cards from your exact Progressive Industries or Hughes Power Watchdog manual
  • Maker-approved generator bonding plug. Clearly labeled for floating-neutral portable generators only, when specified by your manuals.
  • Listed heavy-duty RV plug adapters inspected regularly for clean, tight ground pins

Common Questions

Does E2 mean the same thing on Progressive Industries and Hughes Power Watchdog?

No! On a Progressive Industries surge protector, E2 means an active Open Ground (and PE2 means Previous Error Open Ground) on a 50-amp Hughes Power Watchdog, E2 means a Line 2 voltage fault. High or low voltage on Line 2. Meanwhile, Open Ground on a Hughes Power Watchdog is Code E7. Always check the code chart for your exact surge protector brand.

Why shouldn’t I just plug into the 20-amp or 50-amp outlet on the same campground post if the 30-amp outlet shows an open ground?

An open-ground or neutral fault inside a campground power post often involves the main equipment grounding bar or feeder cable serving the entire power post box. If a power post reports a wiring fault, shut the breaker off, unplug, and have campground staff and a qualified electrician clear the power post rather than testing other outlets on the same box.

When is a neutral-ground bonding plug used, and when is it dangerous?

A neutral-ground bonding plug is an accessory designed only for portable generators that have a floating neutral when powering an RV through an surge protector that checks for a neutral-ground bond. Never use a bonding plug on a campground power post, household outlet, or a generator that already has a bonded neutral, or when an onboard inverter/charger creates its own bond. Always verify the exact generator, RV, and surge protector manuals first.